          H53-32 Epoxy zinc phosphate antirust paint

          Product introduction

          Form :
          Main characteristics :
          Purpose :
          Appearance :

          Composed of epoxy resin, polyamide curing agent, zinc phosphate, red iron oxide and other pollution-free rust paint, additives and solvents composed of two-component epoxy antirust paint

          Key Features

          ¡¤ The use of pollution-free anti-rust paint is conducive to environmental protection

          ¡¤ The film has good water resistance, salt water resistance and salt spray resistance

          ¡¤ Film has good anti-rust and durability

          ¡¤ Excellent adhesion and impact resistance

          ¡¤ Good oil resistance and solvent resistance

          With epoxy, polyurethane and other topcoats have a good matching, and has good adhesion between the layers

          Uses Applicable to steel structures such as ports, docks, shipbuilding, heavy machinery, power machinery, chemical industry, mining machinery, water conservancy projects and steel structures above the waterline of ships.

          Appearance iron red, gray, no light

          Construction parameters

                        Volume of solid 52 ¡À 3% (according to GB / T9272 eqv ISO3233: 1998 provisions) (after mixing)

                        Component A: Component B = 26: 3 (weight ratio)

                        Dry film thickness 50mm

                        Wet film thickness 96mm

                        Theoretical amount of 144g / m2

                        A flash point of 27 ¡æ

                                       Group B 27 ¡æ

                        Drying time (25 ¡æ)

                                    Table ¡Ü 2h

                                    Hard work ¡Ü 24h

                                    Fully cured 7d

          Curing time (after mixing) (20 ¡ã C) 30 min

          Available time (after mixing)

          The temperature

          5¡æ

          20¡æ

          30¡æ

          40¡æ

          Available time

          12h

          8h

          6h

          4h

          Overcoating interval time

          The temperature

          5¡æ

          20¡æ

          30¡æ

          40¡æ

          The shortest

          48h

          24h

          16h

          8h

          The longest

          14d

          7d

          5d

          5d

          It is recommended to spray the coating with no air or spray 1-2 Road, brush, roller 2-3 Road, dry film thickness greater than 100mm.

          Before the road supporting paint H06-4 epoxy zinc-rich anti-rust paint, E06-1 inorganic zinc silicate antirust paint, or direct painting in the derusting quality to Sa2.5 level steel surface.

          After the Road supporting paint 842 epoxy cloud iron antirust paint, or epoxy-type finish, polyurethane topcoat.

          Surface treatment

                        * There are oxide steel: sandblasting to Sa2.5 level

                        * No oxide steel: sandblasting to Sa2.5 level or to the abrasive wheel grinding to St3 level

                        • Steel coated with shop primer: sandblasted or sanded with a flexible grinding wheel to St3 level

                        ¡¤ Welding, flame cutting or firework correction Burning parts: remove welding slag, splash, polished smooth, with elastic grinding wheel to St3 level

          Construction conditions

                        • Substrate temperature should be above 3 ¡æ above dew point

                        ¡¤ When the temperature is lower than 5 ¡æ, curing reaction of epoxy and curing agent is stopped, so it is not suitable for outdoor construction

                        ¡¤ Relative humidity not more than 85%

          Coating method

          Airless spray

                    Diluent 103 Diluent

                    Dilution 0-5% (by weight of paint)

                    Nozzle diameter 0.4-0.5mm

                    The discharge pressure is 20 to 25 MPa (about 200 to 250 kg / cm2)

          Air spraying

                    Not recommended for large areas of construction, only for small areas of repair or small to be painted parts

                    Diluent 103 Diluent

                    Dilution 0-10% (by weight of paint)

                    Nozzle diameter of 2.0-3.0mm

                    Air pressure 0.3-0.4MPa (about 3-4kg / cm2)

          Roll coating / brushing

                        Diluent 103 Diluent

                        Dilution 0-3% (by weight of paint)

          Cleaning agent 103 Thinner

          Safety precautions Refer to the MSDS.

          Packaging a group of 20L barrels 26kg

                           Group B is packed in 3L in 4L

          Shelf life of 12 months

          Remark For the correct use of our products, please carefully read the "User's Guide" in this manual.

          Statement The above data and data are based on our test and practical experience in the use of accumulated and can be used as construction guide. We do not understand the situation in the construction, we only guarantee the quality of the paint itself, other issues will not be responsible. For this manual, we will be based on the continuous improvement of products have the right to modify.