1900 Polyurethane conductive paint is based on isocyanate adduct and hydroxyl-containing polyester resin as the base material, adding two-component coating composed of conductive material. 1900-1 is based on epoxy resin and curing agent for the base material and inert anti-rust paint composed of two-component oil primer. The coating system composed of 1900 conductive paint and 1900-1 primer has the properties of resistance to various petroleum products, has no influence on the quality of oil, has good oil resistance and water resistance, and has good electrical conductivity, and its resistivity is less than 106? ¡¤ Cm, to prevent the accumulation of static electricity inside the tank, to prevent fire hazards, to ensure the safety role. In order to improve the chemical resistance of paint film, 1900 polyurethane conductive paint must be used with the 1900-1 primer. The matching method is as follows:
sequence number | Painting program | Paint Name | Painting Road number | Painting Method | Film thickness (M / track) | Theoretical consumption G / m2 / channel | Painting interval £¨25¡æ£© | ||
Dry film | Wet film | The shortest | longest | ||||||
1 | Surface deal with | To sand blasting for rust treatment, surface treatment quality to be GB8923 "before painting steel Surface rust and rust grades, "the provisions of the Sa2.5 level, surface roughness 35-75¦Ìm | |||||||
2 | Primer | 1900-1 | 1 | Airless spray | 125 | 227 | 299 | 24h | 7d |
3 | Primer | 1900-1 | 1 | Airless spray | 125 | 227 | 299 | 24h | 7d |
4 | Topcoat | 1900 | 1 | Airless spray | 70 | 153 | 175 | 12h | 2d |
5 | Topcoat | 1900 | 1 | Airless spray | 70 | 153 | 175 | 12h | 2d |
6 | Topcoat | 1900 | 1 | Airless spray | 70 | 153 | 175 | 12h | 2d |
* The thickness of one painting in the table is the thickness of the airless spray, and the thickness of the hand brush three is about one airless spray.
First, 1900-1 primer
Composed of epoxy resin, polyamide curing agent, inert anti-rust paint composed of two-component epoxy oil primer.
Key Features
¡¤ Excellent oil resistance to aviation kerosene, gasoline, diesel oil and other petroleum products, and has no effect on the quality of aviation kerosene.
¡¤ Has good water resistance, rust resistance and durability
¡¤ Tough film with good adhesion and mechanical strength.
Use as a 1900 polyurethane conductive paint primer, used for petroleum products storage tanks and oil pipelines and so on.
Appearance iron red
Construction parameters
Volume of solid 55 ¡À 3% (according to GB / T9272 eqv ISO3233: 1998 requirements) (after mixing)
Component A: Component B = 100: 22 (weight ratio)
The dry film thickness was 125 ¦Ìm
The wet film thickness was 227 ¦Ìm
Theoretical amount of 299g / m2
Curing time (after mixing) (25 ¡æ) 30min
Application period (after mixing) (25 ¡æ) 8h
Drying time (25 ¡æ)
Table dry ¡Ü 2h
Hard work ¡Ü 24h
Fully cured 7d
A flash point of 27 ¡æ
Group B 27 ¡æ
Overcoating interval time
The temperature | 5¡æ | 20¡æ | 30¡æ |
The shortest | 48h | 24h | 12h |
The longest | 14d | 7d | 3d |
It is recommended that the number of coating as 1900 polyurethane conductive paint primer, no air spray 2-3 Road, dry film thickness of 250¦Ìm.
Manual coating about 5-6 coating, dry film thickness to achieve 250¦Ìm.
Surface treatment
Sandblasting, rust quality to be achieved Sa2.5 level, surface roughness 35-75¦Ìm
• When servicing the old tank, clean the oil and water from the tank and then sandblast
To Sa2.5 level
Construction conditions
• Substrate temperature should be above 3 ¡æ above dew point
¡¤ When the temperature is lower than 5 ¡æ, curing reaction of epoxy and curing agent is stopped, so it is not suitable for outdoor construction.
¡¤ Relative humidity not more than 85%
Coating method
Airless spray
Diluent 103 Diluent
Dilution 0-5% (by weight of paint)
Nozzle diameter 0.4-0.5mm
The discharge pressure is 20 to 30 MPa (about 200 to 300 kg / cm2)
Roll coating / brushing
Diluent 103 Diluent
Dilution 0-3% (by weight of paint)
Cleaning agent 103 Thinner
Safety precautions Refer to the MSDS.
Packaging A component 20L barrels 15.5kg
Group B 4L barrel 3.4kg
Shelf life of 12 months
Second, 1900 polyurethane conductive paint (topcoat)
& Lt; / RTI & gt;
Two-component polyurethane conductive varnish composed of isocyanate adduct and hydroxyl-containing polyester resin as base material, conductive material, pigment, assistant and solvent.
Key Features
¡¤ Excellent oil resistance to petroleum products such as gasoline, diesel and jet kerosene, and has no effect on oil quality.
¡¤ The film has good electrical conductivity, its resistivity is less than 106¦¸ ¡¤ cm, can prevent the accumulation of static electricity in the oil tank, have the function preventing the fire hidden trouble, ensuring the safety
¡¤ Has good resistance to weak acid, alkali resistance and chemical resistance
* Has a good heat, high pressure steam flushing performance
¡¤ With 1900-1 primer, with good anti-rust performance
Uses
It can be used in the tank, petroleum product storage tank, petrol and aviation kerosene storage tank, oil pipeline and cargo tank interior. It is used for antistatic and antistatic.
The appearance of black plain
Construction parameters
Volume solids 46 ¡À 3% (measured according to ISO / IEC 3233: 1998) (after mixing)
Part A: Part B = 8: 3 (weight ratio)
Dry film thickness of 70¦Ìm
The wet film thickness was 153 ¦Ìm
The theoretical amount of 175g / m2
Flash point of a group of 24 ¡æ
B component 23 ¡æ
Curing time (after mixing) (25 ¡æ) 30min
Pot life (after mixing) (25 ¡æ) 5h
Drying time (25 ¡æ)
Table dry ¡Ü 1h
Hard work ¡Ü 12h
Fully cured 7d
Overcoating interval (25 ¡æ)
The shortest 12h
Up to 2 days
It is recommended to coat the number of coating channels 3, dry film thickness 200¦Ìm.
Surface treatment
¡¤ Clear the 1900-1 primer paint on the oil, dust and all dirt. No acid and alkali on the film and water condensation
¡¤ For primers or topcoats whose curing time has exceeded the maximum allowable interval, the abrasive shall be smeared with sandpaper before the finish
Construction conditions
¡¤ It is not suitable for construction below 0 ¡æ
• Substrate temperature should be above 3 ¡æ above dew point
¡¤ Relative humidity less than 75%
Coating method
Airless spray
Thinner 109 Thinner
Dilution 0-5% (by weight of paint)
Nozzle diameter 0.4-0.5mm
The discharge pressure is 15 to 20 MPa (about 150 to 200 kg / cm2)
Air spraying
Thinner 109 Thinner
Dilution 0-5% (by weight of paint)
The nozzle diameter is 1.5-2.0mm
Air pressure 0.3-0.4MPa (about 3-4kg / cm2)
Roll coating / brushing
Thinner 109 Thinner
Dilution 0-3% (by weight of paint)
Cleaner 109 Thinner
Safety precautions Refer to the MSDS.
Packaging a group of 20L barrels 16kg
Group B 10L barrels 6kg
Shelf life of a group: 12 months
Group B: 6 months
Precautions
¡¤ Oil tank steel plate after sandblasting treatment, in order to prevent re-rust, must be painted within 6 hours of the first 1900-1 primer
¡¤ The relative humidity in tank or tank should not be higher than 75%
* 1900-1 primer and 1900 conductive paint are two-component paint, with the former group B into the first group, or according to the required ratio of deployment, with the number of how much allocation, mixing evenly after use. After the preparation of 1900-1 primer used in 8 hours, 1900 conductive paint used up within 5 hours. Temperature is higher than 25 ¡æ, the pot life is shortened accordingly
¡¤ 1900-1 thinner used in the primer and 1900 thinner used 109 conductive paint must be dedicated, not interchangeable, not to make mistakes, so as not to cause losses
* With paint and coating process, 1900 conductive paint not with water, acid, alkali, alcohol and other contact. 1900
Conductive paint component B is easy to react with water, alcohol and other materials, with paint after the remaining part of the B group of drums must be tightly sealed to avoid the loss of cement
¡¤ Construction tools must be clean and dry, immediately after use with special thinner wash, should not be placed in water
¡¤ In order to make the 1900-1 primer and 1900 conductive paint A, B two components fully cross-linked and cured completely, with paint after 25 ¡æ at the temperature of 30min curing was preserved after the original coating. If the temperature is below 25 ¡æ can be appropriate to extend the aging time
The construction of the tank must pay attention to labor protection, the use of low-pressure lights, to strengthen ventilation, ventilation must meet safety requirements. Construction workers to wear ventilation masks, construction time can not be too long, to regularly out of the tank to breathe fresh air
¡¤ After the construction, must be in a certain period of time to continue to take ventilation measures to discharge paint drying process of evaporation of solvents to ensure that the film drying and curing
¡¤ Do not rush to finish painting, must ensure that adequate drying time, otherwise it will make early vesicles film. Temperature 25 ¡æ in the case of adequate ventilation, at least 7 days before loading oil. Temperature below or above 25 ¡æ, may be appropriate to extend or shorten the drying time
Remark For the correct use of our products, please carefully read the "User's Guide" in this manual.
Statement The above data and data are based on our test and practical experience in the use of accumulated and can be used as construction guide. We do not understand the situation in the construction, we only guarantee the quality of the paint itself, other issues will not be responsible. For this manual, we will be based on the continuous improvement of products have the right to modify.